DTH11 SERIES High Frequency Single Phase UPS (1-10KVA)

Capacity: 1-10KVA UPS
Features: tower, single phase in, single phase out, transformer-free,Output PF=1, UPS Advanced Technology,Outstanding Flexibility
Battery: external/internal
Color: Black
Description: DTH11 SERIES is single phase high frequency UPS 1KVA-10KVA

Application Field
Computers, data center, network device,telecommunication,precision instrument.

Performance characteristics
Advanced Technology
1.DSP digital controlling technology.
2.50/60Hz auto sensing.
3.Wide input voltage range.
4.Automatic recovery function.

Outstanding Flexibility
1.Adjustable battery numbers for 6-10KVA.
2.Adjustable charging current.
3.Comprehensive display allows easy monitoring.
4.Maintenance bypass(optional).

Green Performance
1.Input power factor ≥0.99.
2.ECO mode for energy saving.
3.Output Power=1.

Performance

Model

DTH11-1K

DTH11-1KL

DTH11-2K

DTH11-2KL

DTH11-3K

DTH11-3KL

DTH11-6K 

DTH11-6KL

DTH11-10K

DTH11-10KL

Capacity

1kVA

2kVA

3kVA

6kVA

10kVA

Input

Voltage Range

110300Vac (110~176VAC/276~300VAC at different power)

Frequency Range

44~56Hz@ 50Hz system or 54Hz~66Hz @ 60Hz system

Power Factor

≥0.99@100% load

Output

Output

208/220/230/240VAC(208V should be set from LCD with derating 10%)

Voltage Accuracy

±1%

Frequency Range (Battery mode)

50/60Hz±0.1%

Overload Capacity

Line mode: 30min@102%~110% Load 10min@110%~130% Load 30S@130%~150% Load 500ms@>150% Load

Batter ymode: 10min@102%~110% Load, 1min@110%~130% Load 10s@130%~150% Load500ms@>150% Load

Power Factor

1

Peak Current Ratio

3:1

Voltage Waveform Distortion

≤2% @ 100% linear load ≤5% @ 100% Nonlinear load

≤2% @ 100% Linear load ≤4% @ 100% Nonlinear load

Switching

Time

Main

power             

Battery

ms

Inverter       Bypass

<4 ms

Efficiency

AC/AC Mode

>93%

>94%

>94%

> 95.5%

> 95.5%

Battery

Standard

Model

12V / 7Ah

Number

2

4

6

16(16~20 settable)

Charging Current

1A

1A; max: 2A optional

Rated  Voltage

24

48

72

192(192-240 settable)

Long

Backup

Charging Current

1-12A settable

Rated  Voltage

36

72

96

192(192-240 settable)

Other

Protection

Low battery power off, Battery overcharge protection, Battery leakage current, Battery over discharge, Short circuit

Alarm

Battery Low Voltage, Charger Failure, UPS failure, UPS failure, Bypass

Display

LCD display UPS running status

Environment

Working Condition

Relative Humidity 20%-95% and temperature 0-40

Noise

< 50dB(A)@ 1 meter

Management

Communication Interface

RS232,EPO ,USB(SNMP optional in slot)

Physical Characteristics

Standard

Size WxDxH(mm)

145x276x225

145x276x225

190x395x325

200x460x775

200x460x775

Net weight (kg)

9.6

18

25

55

55.25

Long

Backup

Size WxDxH(mm)

145x276x225

145x276x225

145x392x225

190x395x325

190x395x325

Net weight (kg)

5

10

10.5

8.8

9.6

* The product is subject to actual product,The above specifications  are subject to change without notice


Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
Transformerless three phase KEHUA KSTAR EAST UPS
DTH33 SERIES (10-200KVA)DTH33 SERIES High Frequency UPS (10-200KVA)
Capacity: 10-200KVA UPS Features: tower, three phase in, three phase out,Output PF=0.9 UPS Advanced Technology,Outstanding Flexibility Battery: external Color: Black Description: DTH33 SERIES is three phase high frequency UPS 10KVA-200KVA
Transformerless three phase KEHUA KSTAR EAST UPS
DTH31 SERIES Transformer-less UPS (10-20KVA)
Capacity: 10-20KVA UPS Features: tower, three phase in, single phase out, transformer-free,Output PF=0.9 UPS Advanced Technology,Outstanding Flexibility Battery: external Color: Black Description: DTH31 SERIES is three phase high frequency UPS 10KVA-20KVA
Transformerless single phase 2U KEHUA KSTAR EAST UPS
DTH-R SERIES Rack Mount UPS(1-10KVA)
Capacity: 1-10KVA UPS Features: 19" rack mounted, single phase in, single phase out, transformer-free,Output PF=1, UPS Advanced Technology,Outstanding Flexibility Color: Black Discription: DTH-R SERIES is single phase high frequency UPS 1KVA-10KVA
Power Distribution Cabinets
Server Rack Cabinets
Product Name:Power Distribution Cabinets Type: Rack or 19' cabinet Specification: Customized
48V DC power supply
5G DC POWER SUPPLY
Capacity: 1KVA-6KVA Inverter Features: Wide working temperature : -40℃~55℃; Output 48Vdc and 280Vdc modules for selection; Modular design for easy installation; IP65 for outdoor Description: HW SERIES is 5G POWER SUPPLY for telecommunication with 48Vdc output and 45V50AH lithium battery inside. It's IP65 design.
parallel-redundant data center HUAWEI EATON APC modular UPS
HQ-M SERIES(MODULAR UPS 20KVA-300KVA)
Capacity: 20-300KVA UPS Features:  20/25KVA 2U module, Output PF=1 UPS, Isolated air duct design,Intelligent Flexibility,High Reliability Battery: external Color: Black Description: HQ-M SERIES is 3 phase MODULAR UPS from 20KVA-300KVA
Vehicle Power supply
EV Pure Sine Wave Inverter for Vehicles(1-3KVA)
Capacity: 1-3kVA Battery: 12V lead acid(not included) Product Introduction: EV portable inverter could supply a steady pure sine wave AC to various load on board, such as coffee machine, microwave, hairdryer or sensitive electronics. It could bring home comfort and convenience for your life or work on board, either motor home or utility vehicle.
Modular data center
Micro Size-X1 Data Center solution
Product name: X1 Modular Data Center Solution(All-in-one Cabinet) Cabinet Number:1 Cabinet Size: 600*1200*2000mm UPS Capacity: 3~10kVA Refrigeration Capacity: 3.5~8kW PDU:2*8-bit 10A Monitoring Diplay: 10 inch Touch Screen Product introduction: As "cloud computing + edge computing" will become a new data processing mode, micro / small IDC will be the most preferred solutions for users. X1 single cabinet micro modular data center perfectly integrates the infrastructure of data center, which combined with the distributed power system DPS (or UPS + maintenance free lead-acid battery), power distribution, rack mounted y air conditioning, emergency ventilation, monitoring, fire protection and other subsystems in a closed cabinet. It is more simple, practical, safe and reliable by reducing the difficulty of computer room planning and implementation for users.
Subscribe To Our Newsletter
Sign up to our newsletter for the construction machinery.

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

whatsapp