Application Field
Medical equipment, data centers, precision instrument,banks, ETC, industrial production lines&controlling system.
Performance Characteristics
Safety and Reliability
1.MCU control to ensure higher reliability.
2.Wide Input Voltage and Frequency Range.
3.Maintenance bypass switch.
4.Cold start function.
Comprehensive Protection
1.Independent air duct to split air flow.
2.Output Isolation transformer.
3.N+X parallel function.
4.Support dual input.
5.Fitting for high-temperature, dusty, salinity&Corrosive gas environment.
Intelligent Management
1.Advanced Battery Management system.
2.RS232/RS484 communication port, dry contact&SNMP optional.
3.Settable charge current according to battery capacity.
Performance
Model |
HQ30L |
HQ50L |
HQ60L |
HQ1110L |
HQ3110L |
HQ3115L |
HQ3120L |
HQ3130L |
Rated Capacity |
3KVA |
5KVA |
6KVA |
10KVA |
10KVA |
15KVA |
20KVA |
30KVA |
Input |
||||||||
Voltage Range |
Single Phase(L+N+G)165Vac~275Vac |
Three Phase |
||||||
Frequency Range |
50±5%Hz |
|||||||
Frequency Tracking |
≤1Hz/s |
|||||||
Output |
||||||||
Voltage Range |
Single Phase 220Vac± 1% |
|||||||
Frequency Range |
50Hz±5%(Mains power);50Hz±0.5%(Battery) |
|||||||
Dynamic Response |
±3%(100% Load change) |
|||||||
THD |
≤3%(100%Linear load);≤5%(100%Non-linear load) |
|||||||
Crest Factor |
3:1 |
|||||||
Parallel Load CurrentImbalance |
≤3% |
|||||||
Power Factor |
0.8 |
|||||||
Overload Capacity |
110%~125% Last 10 Mins;<150% Last 1 Min |
|||||||
Switching Time |
0ms |
|||||||
Efficiency |
≥90%@100% Load |
|||||||
Battery |
||||||||
Type |
Sealed maintenance-free lead-acid battery |
|||||||
DC Voltage |
96Vdc/192Vdc |
192VDC |
||||||
Charging Current |
Optional according to needs |
|||||||
Display |
||||||||
LED Indicator |
Mains lights, inverter lights, battery under voltage lights, bypass lights, overload lights, fault lights |
|||||||
LCD Display |
English display, input and output voltage and frequency, battery voltage, load percentage, UPS status,operating temperature, etc |
|||||||
Other Functions |
||||||||
Alarm Function |
Mains power failure, low battery, output overload, UPS abnormality, etc. |
|||||||
Protection Function |
Overload: switch to bypass power supply, and automatically switch to inverter after reducing theload; overheat: switch to bypass power supply at >85℃; short circuit: automatically limit current and cut off the output |
|||||||
Protection Function |
Fault: switch to bypass power supply; overvoltage protection: UPS output overvoltage switch to bypass; under voltage protection: battery under voltage shutdown UPS output |
|||||||
Environment |
||||||||
Operating Temperature |
0~40℃ |
|||||||
Nosie |
<60dB@1 meter |
|||||||
Communication |
||||||||
Interface |
RS232、RS485;Optional:dry contact,SNMP |
|||||||
Physical |
||||||||
WxDxH(mm)) |
260x550x520 |
350x660x750 |
400x750x900 |
|||||
Weight |
35 |
48 |
52 |
101 |
128 |
142 |
210 |
230 |
* Specifications are subject to change without prior notice