Modular UPS 400KVA-600KVA

  • Modular UPS 400KVA-600KVA
  • video
  • EVADA
  • CHINA
  • 30days
  • 500 units/month
  • HQ-M 400KVA-600KVA
HQ-M 400KVA-600KVA Modular UPS – a scalable UPS device offering flexibility with 50kVA UPS modules (available in the range of 400kVA to 600kVA). This UPS power supply is engineered for reliability and efficiency, providing adaptable power solutions for a wide range of industry applications.

ABOUT HQ-M 3 PHASE 400-600KVA MODULAR UPS

Utilizations: Financial services, telecommunications, education, transportation power, tax administration, healthcare, enterprise operations, petrochemical industries, and more.


◆FEATURE


Three phase modular UPS

Intelligent Flexibility

*30-44 units battery configurable

*Hot-swappable bypass/power module

*Allowing common battery group for parallel

*Fan speed automatically adjusts according to the load

*Multiple communication methods

*Cold start function

double conversion online ups

High Reliability

*Distributed control system for power module

*Isolated air duct for key components

*BMS monitors battery information in real time

*Power module N+X redundancy design50kVA

*Module with display&indicators

ups backup systems

Green Performance

*Efficiency up to 96%

*Output PF = 1 

*Maintenance bypass mode

*THDi < 3% and input PF > 0.99

*ECO mode efficiency up to 99%


◆OTHER


Module UPS

Hot swappable module for easy operation

3 Phase Power Supplies

3 Phase Input, 3 Phase Output

50kVA UPS

Capacity: 200kVA-1200kVA

UPS Power Supply

Efficiency: up to 96%


SPECIFICATION


ModelHQ-M200/50HQ-M300/50HQ-M500/50HQ-M600/60 HQ-M840/60HQ-M1000/50HQ-M1200/60
Rated Capacity200kVA300kVA500kVA600kVA840kVA   1000kVA1200kVA
Power Module Capacity50kVA60kVA
 50kVA60kVA
Power Module Quantity46  10                     14 20
Input
Wiring Method3 Phase+N+PE
Rated Voltage380/400/415VAC(line-line)
Rated Frequency50/60Hz
Voltage Range304VAC~478VAC(line-line)full load;304VAC~228VAC(line-line)load derating linearly from 100%to 80%
Frequency Range40Hz~70Hz
Power Factor>0.99
THDi<3%(linear full load);<5%(non-linear full load)
Bypass
Rated Voltage380/400/415VAC(line voltage)
Voltage RangeFactory setting-20%~+15%;settable,upper limit:+10%,+15%,+20%;lower limit-10%,-20%,-30%,40%
Frequency RangeSettable(±1Hz,±3Hz,±5Hz)
Overload Capacity110%for long run,>150%for 200ms
Battery
Battery Voltage±192VDC(384~528VDC;32~44 units settable,defaulted by 32 units)
Output
Rated Voltage380V/400V/415V(line-line)
Power Factor0.9 (1 optional)
Rated Frequency50/60Hz
Voltage Accuracy≤±1.0%@balanced load;≤±5.0%@unbalanced load
Frequency Accurac50/60Hz±0.01%
Frequency Tracking RangeSettable,±0.5Hz~±5Hz;factory setting±3Hz
THDu≤2%(100%linear load),≤4%(nonlinear load)
Three-phase Phase Accuracy                                                             120°±1°
Crest Factor3:1
Overload<105%,long run;<110%,60mins;110~125%,10mins;>125~150%,1mins;>150%,200ms
System
Efficiency96.5%@double conversion mode
Display10.4"touch screen+LED
WiringSupport top in and bottom in
StandardEC62040-1-1;IEC62040-2;IEC62040-3
Protection ClassP20
OptionalSNMP card、modbus card、parallel components,lightning protection components,dust-proof net,LBS,editable dry contact
Working ConditionTemperature:0~40℃;humidity:0~95%(no condensation)
Noise<70dB @1meter
Altitude<1000 meters,no derating,>1000 meters,derating 1%if every 100 meters increased
Cabinet Type4+1 Modules6+1 Modules10+2 Modules14 Modules20 Modules
Size
System  WxDxH(mm)600x850x2000600x1100x2000   1000x1100x20001800x850x20002000x1100x2000
Module  WxDxH(mm)440x720x130(3U)
Weight
System(kg)19025050053098011001180
Module(kg)33.5